Hospital Operating Room Theatre Light, LED Surgical Lamp Model: MCO-D78/D61 MCO-D78/D61 shadowless LED Operating light is suitable for the requirements of various operation conditions and it is ideal operating lighting equipment for modern operation rooms and clean operation rooms. Technical Data (in 1m distance) MCO-D78 MCO-D61 Diameter of light heads [mm] 780 610 Max Central Illuminance at 4,500 K [Lux] 180,000 160,000 Illuminance Measured Adjustable [Lux] 60,000-180,000 60,000-160,000 Colour temperature (standard) [K] 4500 4500 Color temperature Adjustable [K] 3500,4000,4500 3500,4000,4500 CRI (Color rendering index) [Ra] ≥95 ≥95 Red Color Index (R9) [R9] ≥93 With out (R9) Light Field, d10 [mm] 180±15 160±15 Light Field, d50 [mm] 100±15 80±15 Light field diameter adjustable [mm] 220-300 200-280 The way of adjustalbe light field diameter Electrically Electrically Depth of illumination (L1 + L2) [cm] 110 130 Heat-to-light ratio [mW/m2-lx] 3.3 3.3 Temperature increase in head area Approx [°C] ≤2 ≤2 Light sources [pcs] 111 high performance LED 72 high performance LED Life time light sources [h] 50000 50000 Max. Power consumption of all light sources [W] 111 72 Power supply 24 V AC/DC, 100 V - 240 V AC 24 V AC/DC, 100 V - 240 V AC Ceiling height for installation [cm] 270-320 270-320 Hospital Operating Room Theatre Light, LED Surgical Lamp Model: MCO-D78/D61 MCO-D78/D61 shadowless LED Operating light is suitable for the requirements of various operation conditions and it is ideal operating lighting equipment for modern operation rooms and clean operation rooms. Technical Data (in 1m distance) MCO-D78 MCO-D61 Diameter of light heads [mm] 780 610 Max Central Illuminance at 4,500 K [Lux] 180,000 160,000 Illuminance Measured Adjustable [Lux] 60,000-180,000 60,000-160,000 Colour temperature (standard) [K] 4500 4500 Color temperature Adjustable [K] 3500,4000,4500 3500,4000,4500 CRI (Color rendering index) [Ra] ≥95 ≥95 Red Color Index (R9) [R9] ≥93 With out (R9) Light Field, d10 [mm] 180±15 160±15 Light Field, d50 [mm] 100±15 80±15 Light field diameter adjustable [mm] 220-300 200-280 The way of adjustalbe light field diameter Electrically Electrically Depth of illumination (L1 + L2) [cm] 110 130 Heat-to-light ratio [mW/m2-lx] 3.3 3.3 Temperature increase in head area Approx [°C] ≤2 ≤2 Light sources [pcs] 111 high performance LED 72 high performance LED Life time light sources [h] 50000 50000 Max. Power consumption of all light sources [W] 111 72 Power supply 24 V AC/DC, 100 V - 240 V AC 24 V AC/DC, 100 V - 240 V AC Ceiling height for installation [cm] 270-320 270-320 Sodium Hypochlorite,Calcium Hypochlorite,Calcium Hypochlorite 65 Xuzhou First Chemical Co., Ltd , http://www.chfertilizer.com
Â
1 An imported LED cold light source is adopted as operation lighting. As a genuine cold light source, there is almost no temperature rise at the doctor's head or the wound.
2 The white LED has a feature of color temperature which is different from the light source of common shadowless lamps for operation. It may enhance the chromatic aberration between blood, other body tissues and organs, and it thus helps the operating doctor to have a clearer view.
3 Digital means are adopted for stepless regulation of LED brightness. The operator may adjust the brightness based on his/her own brightness adaptability.
4 The color temperature can be adjusted as preferred or according to the type of surgery.
5 The LED shadowless lamp is pure-DC power supplied, without any strobe or harmonic interference with other equipment in the working area.
6 The imported switch power supply is adopted to control the voltage, making the work voltage permanently stable.
7 The removable handle sheath can be disinfected at the high temperature of 135 ∩.
8 A special optical system is adopted so that the light is evenly illuminated on the observed objects in 360∑, without any virtual image and with high definition.
9 The service life of LED shadowless lamp is long (50,000h), far longer than that of traditional tungsten halogen lamp (1,500h), and it is over twenty times of the service life of energy saving lamp.
10 LED has high luminous efficiency and it is impact-resistant and strong to resist crumbling, without mercury contamination. The light it sends contains no infra-red or ultraviolet radiation pollution.
11 The no welding titanium alloy arm and the streamline-designed lamp cap better meet the design requirements of modern clean laminar flow operation rooms. Its fashionable appearance provides a new attraction for hospital operation rooms.
Â
Â
What are the parameters of our led surgical lamp?
Â
Â
Â
1 An imported LED cold light source is adopted as operation lighting. As a genuine cold light source, there is almost no temperature rise at the doctor's head or the wound.
2 The white LED has a feature of color temperature which is different from the light source of common shadowless lamps for operation. It may enhance the chromatic aberration between blood, other body tissues and organs, and it thus helps the operating doctor to have a clearer view.
3 Digital means are adopted for stepless regulation of LED brightness. The operator may adjust the brightness based on his/her own brightness adaptability.
4 The color temperature can be adjusted as preferred or according to the type of surgery.
5 The LED shadowless lamp is pure-DC power supplied, without any strobe or harmonic interference with other equipment in the working area.
6 The imported switch power supply is adopted to control the voltage, making the work voltage permanently stable.
7 The removable handle sheath can be disinfected at the high temperature of 135 ∩.
8 A special optical system is adopted so that the light is evenly illuminated on the observed objects in 360∑, without any virtual image and with high definition.
9 The service life of LED shadowless lamp is long (50,000h), far longer than that of traditional tungsten halogen lamp (1,500h), and it is over twenty times of the service life of energy saving lamp.
10 LED has high luminous efficiency and it is impact-resistant and strong to resist crumbling, without mercury contamination. The light it sends contains no infra-red or ultraviolet radiation pollution.
11 The no welding titanium alloy arm and the streamline-designed lamp cap better meet the design requirements of modern clean laminar flow operation rooms. Its fashionable appearance provides a new attraction for hospital operation rooms.
Â
Â
What are the parameters of our led surgical lamp?
Â
Â
Hospital Operating Room Theatre Light, LED Surgical Lamp
Model NO.: MCO-D78/D61
Power Supply: 24 V AC/DC, 100 V - 240 V AC
Color Temperature Adjustable [K]: 3500, 4000, 4500
Colour Temperature (Standard) [K]: 4500
Color Rendering Index [Ra]: ≥95
Red Color Index [R9]: D78:≥93 D61:with out (R9)
Trademark: Mecan
Transport Package: Standard Package for Export
Origin: Guangzhou
Model NO.: MCO-D78/D61
Power Supply: 24 V AC/DC, 100 V - 240 V AC
Color Temperature Adjustable [K]: 3500, 4000, 4500
Colour Temperature (Standard) [K]: 4500
Color Rendering Index [Ra]: ≥95
Red Color Index [R9]: D78:≥93 D61:with out (R9)
Trademark: Mecan
Transport Package: Standard Package for Export
Origin: Guangzhou